LA GARD 704 is an electronic lock from the new LA GARD 700 Series, with master, 2 managers, 47 users, time delay, time lock, 2,000 event audit and OLED display. Suitable for commercial and banking use.
LA GARD 704 has options which are configurable using the keypad. Safelock Systems has a standard specification which covers most applications. Should alternative settings be required, they can be changed using the keypad. Please refer to user operating instructions.
1 Master (ID 00)
2 Managers (Any IDs 01-49)
47 Users (Any IDs 01-49)
Any user can be profiled to override time delay, using the keypad
Optional. Dual mode can be selected by the Master using the keypad.
Time delay 00-99 minutes
Open window 01-60 minutes
2,000 events with real time and date
Access to the lock’s stored audit data requires Windows software and peripheral equipment, sold separately
Audit event codes can be viewed using the keypad showing the last 50 events.
Audit events are written using the time and date as the lock perceives it, as such it is important to input the time and date on first use, if there has been a power loss, and annually. When supplied by Safelock Systems, the clock time will change for Daylight Savings Time according to UK settings
Optional silent alarm (Duress) which can be turned on using the keypad
Optional input signal response: Remote disable OR override time delay OR override dual mode which can be selected using the keypad
Peripheral equipment is required to use the lock’s alarm interface features, sold separately
Weekly opening and closing time lock
Holidays
Peripheral equipment and software sold separately is required to program timelock parameters into the lock.
Timelock is applied according to time and date as the lock perceives it, as such it is important to input the time and date on first use, after a power loss, and annually. When supplied by Safelock Systems, the clock time will change for Daylight Savings Time according to UK settings
Optional backlight
Silence keypad sounds
Updatable firmware (Requires Windows software and peripheral equipment sold separately)
Multi-lock: One 704 keypad can control up to 5 locks, available on request
Consecutive entry of 4 incorrect codes initiates a 5-minute penalty period
LA GARD 704 is usually powered by 2 x 9v alkaline batteries housed in the keypad. When the low-profile keypad is used, a separate battery box with 2 x 9v alkaline batteries must be fitted inside the container. 704 can also be powered from the mains with peripheral equipment.
LA GARD 700 Series has updatable firmware which allows for bugs fixes, new features and performance improvements.
Inevitably, this can change how the lock operates. As such different user instructions might apply depending on the firmware versions of the lock that is installed. Safelock Systems will only ever publish instructions for the most recent firmware release on lock pages. The firmware version of the installed lock can be ascertained using the guide on THIS PAGE, where is is also possible to download older operating instructions.