TL11 is a LA GARD electronic lock with master, manager and 8 users, timelock, time delay and 479 event audit. Suitable for commercial use and banking use.
TL11 has configurable options, which are fixed once the lock has been set up. Safelock Systems has a standard specification which covers most applications. Should alternative settings be required, they can be specified on purchase, or discussed in greater detail. Any feature here listed as ‘available on request’ is an example of an alternative setting.
The timelock feature requires software and peripheral equipment to specify parameters within the lock.
1 Master
1 Manager
8 Users (IDs 2-9)
Time Delay Override User (ID 9, available on request)
Available on request
Time delay 1-99 minutes
Open window 1-19 minutes
479 events with time and date
Access to the lock’s stored audit data requires Windows software and peripheral equipment
Silent alarm, available on request
Remote disable opening, or remote disable functions, available on request
Peripheral equipment is required to use the lock’s alarm interface features
Weekly opening and closing
32 opening or closing periods
Immediate timelock or opening extension
DST change procedure using the keypad
Peripheral equipment and software is required to program timelock parameters into the lock. It is advisable to synchronise the lock’s time with a PC on a regular basis to prevent clock drift.
Consecutive entry of 4 incorrect codes initiates a 5-minute penalty period
TL11 must be powered continuously to retain the lock’s time, as such a large battery box is advised. It can also be powered from an alarm system or using mains power with peripheral equipment.