TechMaster is a Tecnosicurezza electronic lock with master, manager, 89 users, time delay, 6,000 event audit, timelock, networking and OTC. Suitable for complex commercial and banking use.
TechMaster has many configurable options, which are are fixed once the lock has been setup. Safelock Systems has a standard specification which covers most applications. Should alternative settings be required, they can be specified on purchase, or discussed in greater detail. Any feature here listed as ‘available on request’ is an example of an alternative setting.
1 Master
1 Manager
89 Users (IDs 02-90)
Time delay override users can be programmed from the existing 89 users, available on request
Administrator, available on request
A second master code is available on request
A second manager code, able to manage a separate range of users, is available on request
Available on request
Time delay 1-99 minutes
Open window 1-19 minutes
6,000 events with real time and date
Access to the lock’s stored audit data requires Windows software and peripheral equipment. A basic audit can be viewed using the keypad, which shows lock opening, by which user and with time and date.
Silent alarm, available on request
Remote disable opening, or remote time delay override, available on request
Peripheral equipment is required to use the lock’s alarm interface features
Available on request
Time and timelock programmed from the keypad
Weekly opening and closing timelock
Holiday and special event dates – 30 closing periods, 30 opening periods
Immediate timelock
Automatic DST changes
Additional timelock tables can apply to different users, available on request
Multi-lock: One TechMaster keypad can control up to 5 locks, available on request
Dynamic codes: With peripheral equipment and software, the lock can accept ‘One time codes’, available on request
Networking: with peripheral equipment and software, the lock can be managed remotely, available on request
Consecutive entry of 4 incorrect codes initiates a 5-minute penalty period
TechMaster is usually powered with a large battery box. It can also be powered from an alarm system or using mains power with peripheral equipment, available on request