These instructions refer to Pulse Basic, also known as Pulse (2 user) with the model number beginning T4700. Some instructions also apply to older versions with model numbers EMXX20.
Contents
About Pulse Basic (2 user)
Available users and default codes
| User | Default code |
|---|---|
| Manager | 123456 |
| User | Deleted, 6-digits (Can be added by the Manager) |
Warning: Default codes must be changed immediately.
Special function shortcuts
Some digits can be used to access special functions. Press and hold the relevant key to access the special function, then follow the remaining instruction.
| Shortcut | Special Function |
|---|---|
| Change code | |
| Add user | |
| Disable user | |
| Delete user | |
| Manager code check | |
| Keypad test | |
| Set time delay values |
Visual and audible signals
- Short beep and LED flash
- Button pressed correctly
- Double beep and LED flash
- Code or function entered correctly. See wrong code
- Long beep
- Code or function entered incorrectly
- LED flash every 2 seconds
- Time delay is counting
- LED flash every second and beep every other second
- The open window is counting
- LED flash every 10 seconds
- The lock is in penalty
- Multiple beeps during opening
- Low battery warning. See change battery
Opening and codes
Open the lock
Depending on the construction of the safe or vault, other locks such as key locks may need to be opened first. Any actions required to open the door and lock, should be reversed to close and secure the door and lock.
- Enter a valid 6-digit code
- A double beep sounds. If a long beep sounds the code has not been accepted.
- Within 4 seconds, turn the keypad and/or safe handle
Open the lock when time delay is active
After initial entry of a valid code, the LED flashes every other second. The open window is indicated by LED flashes every second and a beep every other second. During the open window, enter a valid code again.
Change code
Permission: All
Opening codes should be changed and tested with the safe or vault door open where possible.
- Press and hold 0 until
- A double beep sounds, the LED stays on
- Enter current 6-digit code
- A double beep sounds
- Enter new 6-digit code
- A double beep sounds
- Enter new 6-digit code again
- A double beep sounds, the LED turns off
- Test the new code
User management
Add user
If the user code is deleted, it can be added with a new code.
Permission: Manager
- Press and hold 1 until
- A double beep sounds, the LED stays on
- Enter Manager code
- A double beep sounds
- Enter new 6-digit code
- A double beep sounds
- Enter new 6-digit code again
- A double beep sounds, the LED turns off
- Test the new 6-digit code
If a double beep sounds after entering a valid Manager code, the user may already be installed. See Delete user
Disable or enable user
Permission: Manager
The user code can be temporarily disabled and re-enabled
- Press and hold 2 until
- A double beep sounds, the LED stays on
- Enter Manager code
- A double beep sounds which confirms that the users have been disabled if they were enabled, or enabled if they were disabled.
Delete user
Permission: Manager
- Press and hold 3 until
- A double beep sounds, the LED stays on
- Enter Manager code
- A double beep sounds
General operation
Manager code check
Permission: All
This check indicates whether the Manager code has been changed from the default 123456.
- Press and hold 4 until
- A double beep sounds, the LED stays on
- A double beep sounds if the Manager code has been changed from 123456
- A long beep sounds if the Manager code has not been changed from 123456
Keypad test
Permission: All
The keypad membrane is a replaceable part. If keys do not appear to be functioning normally, a keypad test can determine if there are any problems.
- Press and hold 5 until
- A double beep sounds, the LED stays on.
- Press each key in the order 1 2 3 4 5 6 7 8 9 0
- After each key press – a double beep sounds if the key is working, a long beep sounds if the key is not working, or if an incorrect key was pressed. The LED turns off.
Set time delay values
Permission: Manager
Time delay requires a period of time to elapse before the lock can be opened, to prevent users from being forced to open the lock immediately.
- Press and hold 9 until
- A double beep sounds, the LED stays on
- Enter Manager code
- A double beep sounds
- Enter 2-digits to indicate the time delay (01-99 minutes)
- Enter 2 digits to indicate the open window (10-19 minutes)
- A double beep sounds
- Re-enter the 4-digits to confirm
- A double beep sounds, the LED turns off
To increase time delay values, follow the above steps
To reduce or remove time delay, the operation must be performed during the open window before the user or Manager code is entered. To remove time delay use 00 for the time delay and 01 for the open window.
Wrong code and penalty
Entry of an incorrect code results in a long beep. Entry of 4 consecutive incorrect codes results in a 4 minute penalty period, indicated by an LED flash every 10 seconds. Any attempt to enter a code during the penalty restarts the count of 4 minutes.
Troubleshooting
- A long beep sounds on a key press and the LED flashes every 10 seconds
- The lock is in penalty caused by 4 entries of an incorrect code. Wait for the penalty period of 4 minutes to elapse.
- Multiple beeps sound
- The battery is low and should be replaced with a good quality 9v alkaline battery. See change battery
- A key does not beep when pressed
- The batteries may be depleted, see change battery.
- A key may be faulty, undertake a keypad test if any keys are faulty, contact a safe engineer.
- The safe or vault door does not open
- If the lock system is otherwise operating normally, there is a mechanical fault. Contact a safe engineer.
Change battery
Low battery is indicated by a series of beeps during opening. If there is no response from the keypad, the battery may be completely depleted.
The battery cover is located at the 6 o’clock position on the keypad. The procedure is shown in the video below.
Replace with a good quality 9v alkaline battery.