Prior to taking an audit, ensure that the driver and audit software have been downloaded and installed on the computer. Instructions are available here.
These instructions outline the procedure to download audit from a keypad installed with a Dallas key reader, using a cable connection to a PC. For other methods, please click the appropriate link shown at the end of Pulse Pro audit software.
What you’ll need
Audit equipment is available to purchase from our online store, the parts below are required.

Master or Manager code
Take audit
- Connect the molex plug of the magnetic audit and setup cable to the USB interface

- Connect the USB interface to the computer
- Run the audit software and ensure that the USB interface has been detected

- On the Pulse Pro keypad, press and hold 7 until a double beep sounds and the LED stays on
- Enter the Master (ID 80/81) or Manager (ID 60/61) code
- Press P, the LED flashes
- Connect the magnetic audit and setup cable to the port on the keypad

- The LED will flash
- At the computer, in the audit software click Download

- Specify the number of events and click OK

- The audit will download, and the keypad will sound a single beep when the audit is completed.
- A popup will show Operation Done click OK and the screen will show the contents of the audit.